Hostname: page-component-848d4c4894-ndmmz Total loading time: 0 Render date: 2024-06-02T18:47:25.588Z Has data issue: false hasContentIssue false

Internal reference genes with the potential for normalizing quantitative PCR results for oral fluid specimens

Published online by Cambridge University Press:  04 November 2022

Ting-Yu Cheng*
Affiliation:
Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA, USA
Jeffrey J. Zimmerman
Affiliation:
Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA, USA
Luis G. Giménez-Lirola
Affiliation:
Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Iowa State University, Ames, IA, USA
*
Author for correspondence: Ting-Yu Cheng, E-mail: cheng.1784@osu.edu
Rights & Permissions [Opens in a new window]

Abstract

In basic research, testing of oral fluid specimens by real-time quantitative polymerase chain reaction (qPCR) has been used to evaluate changes in gene expression levels following experimental treatments. In diagnostic medicine, qPCR has been used to detect DNA/RNA transcripts indicative of bacterial or viral infections. Normalization of qPCR using endogenous and exogenous reference genes is a well-established strategy for ensuring result comparability by controlling sample-to-sample variation introduced during sampling, storage, and qPCR testing. In this review, the majority of recent publications in human (n = 136) and veterinary (n = 179) medicine did not describe the use of internal reference genes in qPCRs for oral fluid specimens (52.9% animal studies; 57.0% human studies). However, the use of endogenous reference genes has not been fully explored or validated for oral fluid specimens. The lack of valid internal reference genes inherent to the oral fluid matrix will continue to hamper the reliability, reproducibility, and generalizability of oral fluid qPCR assays until this issue is addressed.

Type
Review Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
Copyright © The Author(s), 2022. Published by Cambridge University Press

Oral fluids as a diagnostic specimen

The terms ‘saliva’ and ‘oral fluid’ are often used interchangeably to refer to fluid samples collected from the oral cavity (Kintz et al., Reference Kintz, Cirimele and Ludes2000; Wong, Reference Wong2006). More accurately, saliva is the fluid produced by salivary glands whereas oral fluid is a composite of saliva, serum transudate, mucosal cells and cellular debris, microorganisms, digestive enzymes, and food residues (Schramm et al., Reference Schramm, Smith and Craig1993; Crouch, Reference Crouch2005; Cone and Huestis, Reference Cone and Huestis2007). This review will use the term ‘oral fluid’ as defined by Atkinson et al. (Reference Atkinson, Dawes, Ericson, Fox, Gandara, Malamud, Mandel, Navazesh and Tabak1993): ‘The fluid obtained by insertion of absorptive collectors into the mouth’.

Although various sampling strategies are used for human beings, oral fluid samples in veterinary medicine are usually collected by introducing an absorbent material into the oral cavity (Palmer et al., Reference Palmer, Whipple and Waters2001; Shin et al., Reference Shin, Cho, Cho, Kang, Kim, Kim, Park and Park2004; Cavalcante et al., Reference Cavalcante, Muniz, Jia, Augusto, Troccoli, Medeiros, Dias, Switzer, Soares and Santos2018). Depending on the size of animals, oral fluid samples could be collected by allowing large animals and primates to chew on absorbent material, e.g. cotton rope, or swabbing oral and buccal cavities in small animals (Larghi et al., Reference Larghi, Nebel, Lazaro and Savy1975; Thomas et al., Reference Thomas, Champoux, Suomi and Gunnar1995; Lutz et al., Reference Lutz, Tiefenbacher, Jorgensen, Meyer and Novak2000; Shin et al., Reference Shin, Cho, Cho, Kang, Kim, Kim, Park and Park2004; Smith et al., Reference Smith, Gray, Moxley, Younts-Dahl, Blackford, Hinkley, Hungerford, Milton and Klopfenstein2004; Gomes-Keller et al., Reference Gomes-Keller, Gonczi, Tandon, Riondato, Hofmann-Lehmann, Meli and Lutz2006; Prickett et al., Reference Prickett, Kim, Simer, Yoon and Zimmerman2008; Dietze et al., Reference Dietze, Moritz, Alexandrov, Krstevski, Schlottau, Milovanovic, Hoffmann and Hoffmann2018; Cheng et al., Reference Cheng, Buckley, Van Geelen, Lager, Henao-Diaz, Poonsuk, Pineyro, Baum, Ji, Wang, Main, Zimmerman and Gimenez-Lirola2020).

The presence of viable viral pathogens, pathogen-specific antibody, and nucleic acids in oral fluids has been well-described (Sirisinha and Charupatana, Reference Sirisinha and Charupatana1970; Garrett, Reference Garrett1975; Archibald et al., Reference Archibald, Zon, Groopman, Mclane and Essex1986). In people, the presence of infectious viruses in oral fluid was first demonstrated by bioassay, e.g. clinical signs in cats and monkeys inoculated with oral fluids from humans with mumps (Wollstein, Reference Wollstein1918; Johnson and Goodpasture, Reference Johnson and Goodpasture1934; Henle et al., Reference Henle, Henle, Wendell and Rosenberg1948). Later, it was used to confirm rabies infection in an infant by intracerebral inoculation of Swiss mouse pups with oral fluids from the child (Duffy et al., Reference Duffy, Woolley and Nolting1947). The fact that several viruses including cytomegalovirus, human immunodeficiency virus (HIV) (Groopman et al., Reference Groopman, Salahuddin, Sarngadharan, Markham, Gonda, Sliski and Gallo1984), herpesviruses (Kaufman et al., Reference Kaufman, Brown and Ellison1967; Douglas and Couch, Reference Douglas and Couch1970), Zika virus (Bonaldo et al., Reference Bonaldo, Ribeiro, Lima, Dos Santos, Menezes, Da Cruz, De Mello, Furtado, De Moura, Damasceno, Da Silva, De Castro, Gerber, De Almeida, Lourenco-De-Oliveira, Vasconcelos and Brasil2016), and influenza virus (Vinagre et al., Reference Vinagre, Martinez, Avendano, Landaeta and Pinto2003), added additional evidence to the role of oral fluids as a source of pathogens. In animals, Coxsackie b-1 virus from rabbits (Madonia et al., Reference Madonia, Bahn and Calandra1966), rabies virus from dogs (Larghi et al., Reference Larghi, Nebel, Lazaro and Savy1975), foot-and-mouth disease virus (FMDV) from cattle (Sellers et al., Reference Sellers, Burrows, Mann and Dawe1968), and influenza A virus and porcine reproductive and respiratory syndrome virus (PRRSV) from pigs (Wills et al., Reference Wills, Zimmerman, Yoon, Swenson, Mcginley, Hill, Platt, Christopher-Hennings and Nelson1997; Detmer et al., Reference Detmer, Patnayak, Jiang, Gramer and Goyal2011) can be isolated from oral fluid specimens.

Statement of the problem

In both basic research and diagnostic medicine, the repeatability of quantitative polymerase chain reaction (qPCR) testing is affected by the variation introduced at any point between sample collection and the final test report (Heid et al., Reference Heid, Stevens, Livak and Williams1996; Klein, Reference Klein2002; Hoorfar et al., Reference Hoorfar, Malorny, Abdulmawjood, Cook, Wagner and Fach2004). Ideally, proper controls can be used to verify the integrity of the process accounting for variation. Internal controls that were extracted or amplified concurrently with test samples verify that the procedure was performed correctly and functioned within expected parameters. In addition, external positive amplification controls (template control) containing fixed quantities of purified PCR target nucleic acids may be used to identify run-to-run variation, e.g. concentration of reagents, qPCR profiles, instrument settings. In contrast, external negative amplification controls (non-template controls) are used to detect reagent contamination.

Internal controls are nucleic acids that are either inherent to the specimen matrix (endogenous reference genes) or added (‘spiked’) into test samples (exogenous reference genes) prior to nucleic acid extraction. Importantly, qPCR results can be ‘normalized’ in the context of internal control results to compensate for variation arising from the initial sample nucleic acid quantity and/or concentration, differences among reverse transcription and amplification efficiencies, assay protocols, and/or instrument settings (Vandesompele et al., Reference Vandesompele, De Preter, Pattyn, Poppe, Van Roy, De Paepe and Speleman2002; Bustin and Nolan, Reference Bustin and Nolan2004; Huggett et al., Reference Huggett, Dheda, Bustin and Zumla2005; Bustin et al., Reference Bustin, Benes, Garson, Hellemans, Huggett, Kubista, Mueller, Nolan, Pfaffl, Shipley, Vandesompele and Wittwer2009; Biassoni and Raso, Reference Biassoni and Raso2014). A number of qPCR normalization-compatible internal reference genes have been described for diagnostic matrices in human medicine, e.g. reticulocytes, keratinocytes, oral fluids, bronchoalveolar lavage fluids, tissue samples (Glare et al., Reference Glare, Divjak, Bailey and Walters2002; Silver et al., Reference Silver, Best, Jiang and Thein2006; Bar et al., Reference Bar, Bar and Lehmann2009; Chervoneva et al., Reference Chervoneva, Li, Schulz, Croker, Wilson, Waldman and Hyslop2010; Koppelkamm et al., Reference Koppelkamm, Vennemann, Fracasso, Lutz-Bonengel, Schmidt and Heinrich2010; Martin, Reference Martin2016). In contrast, the use of internal reference genes is less frequently reported in veterinary research, perhaps because of the diversity of specimens and animal species (McIntosh et al., Reference Mcintosh, Tumber, Harding, Krakowka, Ellis and Hill2009; Pol et al., Reference Pol, Deblanc, Oger, Le Dimna, Simon and Le Potier2013; Yan et al., Reference Yan, Toohey-Kurth, Crossley, Bai, Glaser, Tallmadge and Goodman2020). Therefore, the objective of this review is to compare the use of internal reference genes reported in recent human and veterinary qPCR research involving the oral fluid matrix.

Inherent variations in real-time PCR

Although real-time PCR has been used to precisely quantify molecular substances, the data should be interpreted with caution because of the introduction of variations throughout the process. PCR results are typically reported as quantitation cycles (C q), i.e. the number of cycles required for the cumulative fluorescent intensity to meet a pre-determined threshold (Schmittgen and Livak, Reference Schmittgen and Livak2008; Rao et al., Reference Rao, Huang, Zhou and Lin2013). In general terms, samples with a higher initial concentration of target DNA/RNA will require fewer PCR amplification cycles to reach the threshold than those with a lower initial concentration (Schmittgen and Livak, Reference Schmittgen and Livak2008). However, in the laboratory, the C q of any given sample may be affected by extraneous factors, e.g. technicians' proficiency, test protocols, reagents, PCR conditions, and instruments (Johnson et al., Reference Johnson, Nolan, Bustin and Wilks2013; Kralik and Ricchi, Reference Kralik and Ricchi2017). For example, a recent study concluded the process of collecting nasopharyngeal swabs was a significant source of variability and could produce false-negative results in a severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) real-time PCR assay (Basso et al., Reference Basso, Aita, Navaglia, Franchin, Fioretto, Moz, Bozzato, Zambon, Martin, Dal Pra, Crisanti and Plebani2020). To address the problem of variability introduced by extraneous factors, results can be expressed as the DNA/RNA copy number in the sample (absolute quantification) or expressed as the difference in target DNA/RNA (relative quantification) relative to known negative samples (Klein, Reference Klein2002; Schmittgen and Livak, Reference Schmittgen and Livak2008; Kralik and Ricchi, Reference Kralik and Ricchi2017).

Real-time PCR quantification

Absolute quantification converts a C q result to DNA/RNA copy number using either digital qPCR or absolute standard curves. Digital qPCR is done by partitioning a sample into subsamples and then performing qPCR separately on each subsample. Thereafter, the distribution and proportion of subsamples containing molecules of interest are used to estimate the number of DNA/RNA copies based on the Poisson distribution (Dube et al., Reference Dube, Qin and Ramakrishnan2008; Huggett et al., Reference Huggett, Foy, Benes, Emslie, Garson, Haynes, Hellemans, Kubista, Mueller and Nolan2013). Alternatively, absolute quantification based on standard curves uses the relationship between the sample C q and known concentrations of DNA/RNA to interpolate the concentration of target in the sample. Absolute standard curves are typically established by generating C q results of serially diluted standards with known copy numbers of target DNA/RNA.

However, identifying the change of targets in unknown samples relative to negative calibrators may be sufficient for disease surveillance and diagnostic medicine (Livak and Schmittgen, Reference Livak and Schmittgen2001). Relative quantification of qPCR data may be achieved through two approaches: the relative standard curve and the comparative C q (Liu and Saint, Reference Liu and Saint2002). Relative standard curves use methods similar to absolute standard curves except the standards do not have known DNA/RNA copy numbers. Instead, relative standard curves describe the relationship between C q values and the mass of total DNA/RNA for each dilution. The sample C q result can then be interpreted in the context of the relative standard curve. Because both absolute and relative quantification require that standard curves for targets and references be generated in each PCR run to account for run-to-run variation, a comparative C q method (ΔΔC q, pronounced ‘double delta C q’), has been used in gene expression studies (Livak and Schmittgen, Reference Livak and Schmittgen2001; Pfaffl, Reference Pfaffl2001). This method quantifies the expression of a target gene in a treated sample relative to an untreated calibrator in terms of the fold change in gene expression (Rao et al., Reference Rao, Huang, Zhou and Lin2013). Conveniently, the treated sample and untreated calibrator can be collected at different time points, may be derived from different tissues, or obtained from individuals in different treatment groups (Rao et al., Reference Rao, Huang, Zhou and Lin2013). Unlike standard curve methods, the comparative C q method eliminates the need to generate standard curves in each PCR run and, therefore, may be used in high-throughput molecular laboratories performing routine disease diagnostic and surveillance testing.

Real-time PCR data normalization

Data normalization is a statistical procedure designed to control variations introduced in the sampling/testing process and to ensure that results are comparable within and between laboratories (Bylesjö et al., Reference Bylesjö, Cloarec, Rantalainen, Brown, Tauler and Walczak2009; Biassoni and Raso, Reference Biassoni and Raso2014; Filzmoser and Walczak, Reference Filzmoser and Walczak2014). For example, Dahdouh et al. (Reference Dahdouh, Lazaro-Perona, Romero-Gomez, Mingorance and Garcia-Rodriguez2020) contended that direct estimation of SARS-CoV-2 viral load based on raw C qs could neglect variation introduced during the sample collection process, e.g. patient tolerance to nasal swabbing, and concluded that the normalization of raw C qs against marker nucleic acid genes inherent to sampled cell masses or mucosal surfaces should be implemented to ensure the comparability of coronavirus disease 2019 (COVID-19) qPCRs (Dahdouh et al., Reference Dahdouh, Lazaro-Perona, Romero-Gomez, Mingorance and Garcia-Rodriguez2020; Walsh et al., Reference Walsh, Jordan, Clyne, Rohde, Drummond, Byrne, Ahern, Carty, O'brien, O'murchu, O'neill, Smith, Ryan and Harrington2020).

Three methods commonly used for PCR normalization include consistently testing the same amount (mass) of sample, measuring total RNA/DNA, or using endogenous/exogenous reference genes (Huggett et al., Reference Huggett, Dheda, Bustin and Zumla2005):

  1. (1) Testing the same amount of sample is standard practice in molecular and diagnostic laboratories that use standardized protocols, albeit the concentration of detectable target in clinical samples is still affected by sample collection, storage, and handling and, therefore, may not fully represent the initial concentration.

  2. (2) Normalizing qPCR results against the total RNA/DNA content in sample extracts, i.e. prior to PCR, is a more precise approach for controlling sample-to-sample variation (Wang et al., Reference Wang, Zhao, Li, Liu, Ernst, Liu, Liu, Xi and Lei2015). Quantification of total RNA/DNA can be achieved by spectrophotometrically measuring the optical absorbance (OD260) or the fluorescence of dyes that are randomly bound to nucleic acids of the extracted sample (Jones et al., Reference Jones, Yue, Cheung and Singer1998; Green and Sambrook, Reference Green, Sambrook, Green and Sambrook2018). However, using total DNA/RNA for data normalization assumes that the efficiency of reverse-transcription and PCR amplification is identical for each sample, i.e. does not take sample-to-sample variation into account (Bustin, Reference Bustin2002).

  3. (3) The most common approach for qPCR data normalization is to express the C q of target DNA/RNA in the context of the C q of one or more reference genes (Wittwer et al., Reference Wittwer, Herrmann, Moss and Rasmussen1997). To serve this purpose, reference genes must have genetic sequences that differ from the target and be present at predictable concentrations in the sample (Vandesompele et al., Reference Vandesompele, De Preter, Pattyn, Poppe, Van Roy, De Paepe and Speleman2002; Huggett et al., Reference Huggett, Dheda, Bustin and Zumla2005; Bylesjö et al., Reference Bylesjö, Cloarec, Rantalainen, Brown, Tauler and Walczak2009; Guenin et al., Reference Guenin, Mauriat, Pelloux, Van Wuytswinkel, Bellini and Gutierrez2009). Pfaffl (Reference Pfaffl2001) proposed an approach that integrated data normalization and qPCR relative quantification using test sample and negative calibrator results (Equation 1). This method calculates the target-to-reference ratio (R) of the C q difference between a sample and a calibrator (ΔC q) while taking PCR amplification efficiencies for target (E target) and reference (E ref) sequences into account (Pfaffl, Reference Pfaffl2001):

    (1)$$R = \displaystyle{{{( {E_{{\rm target}}} ) }^{\Delta C_{\rm q}_{_{{\rm target\;}( {{\rm calibrator}-{\rm sample}} ) } } }} \over {{( {E_{{\rm ref}}} ) }^{\Delta C_{\rm q}_{_{{\rm ref\;}( {{\rm calibrator}-{\rm sample}} ) } } }}}$$

In gene expression studies, samples collected from individuals with no treatment, or prior to treatment, may be used as negative calibrators and/or as a baseline relative to the expression/detection level of target genes in samples from treated individuals. Therefore, the relative quantity of a target gene in a treated sample is expressed as the fold change relative to an untreated calibrator, using a reference gene as a normalizer (Rao et al., Reference Rao, Huang, Zhou and Lin2013).

Both exogenous and endogenous reference genes have been used for data normalization at the individual sample level (Ke et al., Reference Ke, Chen and Yung2000). Exogenous reference genes are artificially synthesized nucleic acids with genetic sequences distinct from the target's (Huggett et al., Reference Huggett, Dheda, Bustin and Zumla2005). These heterologous genes may be spiked into test samples prior to the DNA/RNA extraction procedure at a fixed copy number or concentration (Yan et al., Reference Yan, Toohey-Kurth, Crossley, Bai, Glaser, Tallmadge and Goodman2020) to monitor the efficiency of DNA/RNA extraction and the integrity of reverse transcription and PCR amplification in test samples (Guenin et al., Reference Guenin, Mauriat, Pelloux, Van Wuytswinkel, Bellini and Gutierrez2009; Johnston et al., Reference Johnston, Gallaher and Czaja2012). In contrast, endogenous reference genes are host-specific nucleic acids inherent to the specimen (Yan et al., Reference Yan, Toohey-Kurth, Crossley, Bai, Glaser, Tallmadge and Goodman2020). Since endogenous reference genes are processed concurrently with target DNA/RNA, the detection of these genes reflects both the sample-to-sample variation in the quantity and quality of initial amplifiable DNA/RNA and the variation introduced by the extraction and amplification procedures (Radonic et al., Reference Radonic, Thulke, Mackay, Landt, Siegert and Nitsche2004).

Internal reference genes in oral fluids

Endogenous reference genes have been widely used in gene expression analyses for the purpose of representing sample nucleic acid concentration and as the gold standard for qPCR data normalization (Vandesompele et al., Reference Vandesompele, De Preter, Pattyn, Poppe, Van Roy, De Paepe and Speleman2002; Bustin et al., Reference Bustin, Benes, Nolan and Pfaffl2005; Huggett et al., Reference Huggett, Dheda, Bustin and Zumla2005). However, the expression of common reference genes depends on a variety of factors, e.g. cell/specimen types, sample quality and handling, age of subjects, animal species, and disease/treatment status (Zhong and Simons, Reference Zhong and Simons1999; Hamalainen et al., Reference Hamalainen, Tubman, Vikman, Kyrola, Ylikoski, Warrington and Lahesmaa2001; Selvey et al., Reference Selvey, Thompson, Matthaei, Lea, Irving and Griffiths2001; Deindl et al., Reference Deindl, Boengler, Van Royen and Schaper2002; Glare et al., Reference Glare, Divjak, Bailey and Walters2002). Thus, endogenous reference genes must be validated for their consistency of expression and/or detection in test specimens and under the conditions in which target genes will be evaluated (Mestdagh et al., Reference Mestdagh, Van Vlierberghe, De Weer, Muth, Westermann, Speleman and Vandesompele2009). Typically, this involves comparing the variation in endogenous gene C qs in samples from subjects with potentially impactful biological characteristics, e.g. age, gender, and disease status (Huggett et al., Reference Huggett, Dheda, Bustin and Zumla2005; Robinson et al., Reference Robinson, Sutherland and Sutherland2007; Becker et al., Reference Becker, Hammerle-Fickinger, Riedmaier and Pfaffl2010).

In this review, qPCR-based gene expression and disease diagnostic studies were evaluated for the use of endogenous and/or exogenous reference standards in oral fluid specimens from non-human vertebrate and human subjects. Initially, the MEDLINE® database was searched (title and abstract fields) on 24 October 2020 for refereed scientific publications containing the following searching terms: (‘saliva*’ or ‘oral fluid*’ or ‘oral swab*’) and (‘qpcr*’ or ‘quantitative pcr*’ or ‘real time pcr*’ or ‘real-time pcr*’ or ‘realtime pcr’ or ‘RT-qPCR’ or ‘qRT-PCR’ or ‘real time RT-PCR’ or ‘real-time RT-PCR’ or ‘realtime RT-PCR’) not (review[Publication Type]). Articles were excluded if not written in English, if not applicable to non-human vertebrate animals, if the oral fluid specimen was not collected by insertion of an absorptive collector into the mouth (Atkinson et al., Reference Atkinson, Dawes, Ericson, Fox, Gandara, Malamud, Mandel, Navazesh and Tabak1993), or if only components of oral fluids, e.g. microorganisms, biofilms, salivary extracellular vesicles, were evaluated. The remaining publications were evaluated for the use of internal endogenous and/or exogenous reference genes. A total of 1566 articles were retrieved from MEDLINE®. For the period 2003–2020, 136 met the language, research subject, and full-text criteria (Table 1). Among these, exogenous reference genes were used in 25.7% (35/136), endogenous reference genes in 27.2% (37/136), and 52.9% (72/136) did not include sufficient information on the use of internal reference genes.

Table 1. Frequency of reference genes reported in published qPCR studies using the oral fluid matrix

ACTB, β-actin; GAPDH, glyceraldehyde-3-phosphate dehydrogenase; rRNAs, 5S, 18S, 28S ribosomal RNAs.

a Buffalo, cattle, deer, goat, and sheep.

b Chipmunk, gerbil, guinea pig, mongoose, mouse, rabbit, rat, shrew, squirrel, and vole.

c Bat, elephant, horse, opossum, poultry, skunk, turtle, and weasel.

d Endogenous reference genes with frequency < 5 pooled.

A similar strategy was used to retrieve oral fluid-based qPCR studies on human subjects from the MEDLINE® database for the articles published between 2016 and 2020. Among the 772 articles retrieved, 184 met the language, species, and content criteria (Table 1).

Exogenous reference genes were used in 14.0% of reviewed studies (25/179), endogenous reference genes in 31.8% (57/179), and 57.0% (102/179) of the studies did not include sufficient information on the use of internal reference genes. As shown in Table 1, β-actin (ACTB) mRNA, ribosomal RNAs (18S and 28S rRNA), and glyceraldehyde-3-phosphate dehydrogenase (GAPDH) mRNA, respectively, were the most frequently used endogenous reference genes in published studies on non-human vertebrates. In human studies, ACTB mRNA, GAPDH mRNA, and U6 small nuclear RNA (snRNA) were the most commonly reported.

Ribosomal RNAs

In mammalian cells, gene expression begins by transcribing DNA into single-stranded messenger RNA (mRNA) in the cell nucleus. From the nucleus, mRNA migrates to the cytoplasm where it is paired with complementary amino acids by ribosomes to build proteins (Sergiev et al., Reference Sergiev, Aleksashin, Chugunova, Polikanov and Dontsova2018). Ribosomes compose two subunits, the small subunit containing the 18S ribosomal RNA (rRNA) and ribosomal proteins, and the large subunit containing 5S, 5.8S, 28S rRNA, and ribosomal proteins (Lafontaine and Tollervey, Reference Lafontaine and Tollervey2001). Since ribosomal genetic material is highly conserved and nearly universal in cell-rich specimens, e.g. cell culture, peripheral blood mononuclear cells, and tissue samples, rRNA is one of the most commonly used internal reference genes for qPCR normalization in gene-expression research (Kozera and Rapacz, Reference Kozera and Rapacz2013; Ban et al., Reference Ban, Beckmann, Cate, Dinman, Dragon, Ellis, Lafontaine, Lindahl, Liljas, Lipton, Mcalear, Moore, Noller, Ortega, Panse, Ramakrishnan, Spahn, Steitz, Tchorzewski, Tollervey, Warren, Williamson, Wilson, Yonath and Yusupov2014). Because the 18S and 28S rRNAs are cleaved from the same single-stranded RNA transcript, the 28S:18S rRNA ratio has been used as an index of the integrity and quality of extracted RNA for electrophoresis-based PCR (Schroeder et al., Reference Schroeder, Mueller, Stocker, Salowsky, Leiber, Gassmann, Lightfoot, Menzel, Granzow and Ragg2006; Becker et al., Reference Becker, Hammerle-Fickinger, Riedmaier and Pfaffl2010). For example, De Ketelaere et al. (Reference De Ketelaere, Goossens, Peelman and Burvenich2006) and Zhao et al. (Reference Zhao, Liu, Li, Yang, Zhao, Liu, Liu, Liu, Yin, Guan and Luo2016) reported 18S rRNA as one of the most consistently expressed genes in bovine polymorphonuclear leukocytes and peripheral blood mononuclear cells (De Ketelaere et al., Reference De Ketelaere, Goossens, Peelman and Burvenich2006; Zhao et al., Reference Zhao, Liu, Li, Yang, Zhao, Liu, Liu, Liu, Yin, Guan and Luo2016). Zhong and Simons (Reference Zhong and Simons1999) concluded that the expression level of 28S rRNA was more consistent in hypoxia-cultured cells than ACTB mRNA, GAPDH mRNA, and cyclophilin mRNA (Zhong and Simons, Reference Zhong and Simons1999; Wang and Heitman, Reference Wang and Heitman2005).

However, the use of rRNAs as internal reference genes in qPCR has several shortcomings. First, their quantity and concentration can vary within specimens from the same species (Ingerslev et al., Reference Ingerslev, Pettersen, Jakobsen, Petersen and Wergeland2006; Rekawiecki et al., Reference Rekawiecki, Kowalik and Kotwica2013). Second, ribosomes are absent from red blood cells and rRNA detection can be inconsistent in specimens in which blood is a significant component. Finally, rRNAs may be overabundant in cell-rich specimens, e.g. peripheral blood mononuclear cells, tissue, and laboratory-cultured cells (Tong et al., Reference Tong, Gao, Wang, Zhou and Zhang2009). As a consequence, when reverse-transcribed and/or amplified simultaneously with the target, they may compete with the target for PCR components, e.g. polymerase, magnesium ions, and dNTP. Furthermore, an overabundance of rRNA increases the risk of cross-contamination during sample handling and testing (Yan et al., Reference Yan, Toohey-Kurth, Crossley, Bai, Glaser, Tallmadge and Goodman2020).

ACTB mRNA

β-Actin, encoded by ACTB mRNA, is an isoform of non-muscle actin protein that primarily serves as a component of the cytoskeleton of eukaryotic cells (Bunnell et al., Reference Bunnell, Burbach, Shimizu and Ervasti2011). ACTB has been used for sample quality assessment and qPCR normalization because of its ubiquitous expression in cells (Hunter and Garrels, Reference Hunter and Garrels1977; Biederman et al., Reference Biederman, Yee and Cortes2004; Johansson et al., Reference Johansson, Fuchs, Okvist, Karimi, Harper, Garrick, Sheedy, Hurd, Bakalkin and Ekstrom2007; Robinson et al., Reference Robinson, Sutherland and Sutherland2007; Ruan and Lai, Reference Ruan and Lai2007; Bar et al., Reference Bar, Bar and Lehmann2009; Die et al., Reference Die, Baldwin, Rowland, Li, Oh, Li, Connor and Ranilla2017), but recent studies have found the expression level of ACTB to vary by animal species, cell and/or specimen type, sample storage time, growth stage, medical treatment, and disease state (Gutala and Reddy, Reference Gutala and Reddy2004; Nishimura et al., Reference Nishimura, Nikawa, Kawano, Nakayama and Ikeda2008; Spalenza et al., Reference Spalenza, Girolami, Bevilacqua, Riondato, Rasero, Nebbia, Sacchi and Martin2011; Panahi et al., Reference Panahi, Salasar Moghaddam, Ghasemi, Hadi Jafari, Shervin Badv, Eskandari and Pedram2016; Khanna et al., Reference Khanna, Johnson and Maron2017; Alshehhi and Haddrill, Reference Alshehhi and Haddrill2019). For example, in human beings, lower expression of ACTB was reported in bronchoalveolar lavage fluid cells and airway endobronchial biopsy samples from asthmatic patients versus clinically normal subjects or subjects treated with inhaled corticosteroids (Glare et al., Reference Glare, Divjak, Bailey and Walters2002). Hamalainen et al. (Reference Hamalainen, Tubman, Vikman, Kyrola, Ylikoski, Warrington and Lahesmaa2001) reported up to 11-fold down-regulation of ACTB expression in T-cells over a 14-day course of T-cell differentiation (Hamalainen et al., Reference Hamalainen, Tubman, Vikman, Kyrola, Ylikoski, Warrington and Lahesmaa2001). In a qPCR reference gene validation study using peripheral blood mononuclear cells and whole blood from healthy and tuberculosis-positive subjects, ACTB showed >30-fold variability in both specimens and was determined to be unsuitable for data normalization (Dheda et al., Reference Dheda, Huggett, Bustin, Johnson, Rook and Zumla2004).

In veterinary studies, the expression of ACTB depends on a number of factors and its use as an internal reference standard requires assessment on a case-by-case basis. Stable expression of ACTB has been reported in feline tissue samples and bovine peripheral blood mononuclear cells (Ingerslev et al., Reference Ingerslev, Pettersen, Jakobsen, Petersen and Wergeland2006; Robinson et al., Reference Robinson, Sutherland and Sutherland2007; Kessler et al., Reference Kessler, Helfer-Hungerbuehler, Cattori, Meli, Zellweger, Ossent, Riond, Reusch, Lutz and Hofmann-Lehmann2009; Jursza et al., Reference Jursza, Skarzynski and Siemieniuch2014), but the expression of ACTB has been reported as low in bovine polymorphonuclear leukocytes (De Ketelaere et al., Reference De Ketelaere, Goossens, Peelman and Burvenich2006). In a study evaluating the expression of 11 housekeeping genes in canine tissue specimens, including bone marrow, various enteric tissues, heart, muscle, pancreas, and spleen, ACTB was found to be the least consistently expressed (Peters et al., Reference Peters, Peeters, Helps and Day2007). Thus, although ACTB has been widely used for data normalization in qPCR studies, care should be taken to validate its consistency of expression in the target species and specimen.

GAPDH mRNA

Encoded by GAPDH mRNA, GAPDH is a cytoplasmic enzyme that facilitates glycolysis, a metabolic pathway to release energy, by converting glyceraldehyde-3-phosphate to 1,3-biphosphoglycerate (Tristan et al., Reference Tristan, Shahani, Sedlak and Sawa2011; Nicholls et al., Reference Nicholls, Li and Liu2012; Alfarouk et al., Reference Alfarouk, Verduzco, Rauch, Muddathir, Adil, Elhassan, Ibrahim, David Polo Orozco, Cardone, Reshkin and Harguindey2014). The ubiquitous expression of GAPDH mRNA in living cells has led to its common use as an endogenous reference control for qPCR normalization in gene expression and disease diagnostic studies (Rebouças et al., Reference Rebouças, Costa, Passos, Passos, Hurk and Silva2013). However, like rRNAs and ACTB mRNAs, the expression of GAPDH mRNA may vary among subjects and treatments. Consistent GAPDH mRNA expression has been reported in oral fluid specimens from premature human neonates, human cervical tissues, and neonatal cardiac ventricular myocytes (Winer et al., Reference Winer, Jung, Shackel and Williams1999; Shen et al., Reference Shen, Li, Ye, Wang, Lu and Xie2010; Maron et al., Reference Maron, Johnson, Dietz, Chen and Bianchi2012). However, the inconsistent expression of GAPDH mRNA has been reported under a number of experimental conditions, e.g. growing collateral arteries of rabbits, asthmatic human subjects with/without corticosteroid treatment, cells cultured under hypoxic conditions, and whole blood from tuberculosis patients (Zhong and Simons, Reference Zhong and Simons1999; Deindl et al., Reference Deindl, Boengler, Van Royen and Schaper2002; Glare et al., Reference Glare, Divjak, Bailey and Walters2002; Dheda et al., Reference Dheda, Huggett, Bustin, Johnson, Rook and Zumla2004). Barber et al. (Reference Barber, Harmer, Coleman and Clark2005) reported up to a 15-fold difference in the expression level of GAPDH mRNA across 72 human tissues (Barber et al., Reference Barber, Harmer, Coleman and Clark2005). Therefore, GAPDH mRNA may not be the appropriate endogenous reference control for the comparison of qPCR results across specimen matrices.

U6 snRNA

After DNA transcription, RNA transcripts undergo modification to become functional mRNAs able to perform protein synthesis (Moore and Proudfoot, Reference Moore and Proudfoot2009). This pre-mRNA processing involves (1) removing introns from pre-mRNAs (splicing); (2) adding a modified guanine nucleotide at the 5′ ends (5′ capping); and (3) adding a long chain of adenine nucleotides at the 3′ end (3′ poly-A tailing). In mammalian cells, U1, U2, U4, U5, and U6 snRNAs complex with RNA-binding proteins to form small nuclear ribonucleoproteins able to perform the splicing activity required to functionalize mRNA (Maniatis and Reed, Reference Maniatis and Reed1987; Brow and Guthrie, Reference Brow and Guthrie1988; Stefl et al., Reference Stefl, Skrisovska and Allain2005). Among five snRNAs, U6 snRNA was the most conserved in size, sequence, and structure across yeast, bean, fly, and mammalian cells (Brow and Guthrie, Reference Brow and Guthrie1988). Because of its small size (~100 nucleotides), U6 snRNA has been used to research the expression of micro RNAs, a group of small single-stranded RNAs known for silencing and interfering with mRNA expressions in plants, animals, and viruses (Bushati and Cohen, Reference Bushati and Cohen2007; Mase et al., Reference Mase, Grasso, Avogaro, D'amato, Tessarolo, Graffigna, Denti and Ravelli2017; Didychuk et al., Reference Didychuk, Butcher and Brow2018). For human samples, U6 snRNA has been used as an internal reference gene for the study of micro-RNA expression in human urinary sediment and serum samples from colorectal adenoma, colorectal adenocarcinoma, and healthy human subjects (Zheng et al., Reference Zheng, Wang, Zhang, Yang, Wang, Du, Li, Li, Qu, Liu and Wang2013; Duan et al., Reference Duan, Cai, Li, Bu, Wang, Yin and Chen2018). However, as observed in other endogenous reference genes, the expression level of U6 snRNA varies among specific specimens and treatments. For example, variation in U6 snRNA expression has been reported in 13 normal and 5 tumorous tissues including colon, esophagus, lung, lymphoid, and prostate (Peltier and Latham, Reference Peltier and Latham2008). Lou et al. (Reference Lou, Ma, Xu, Jiang, Yang, Wang, Jiao and Gao2015) evaluated the expression of U6 snRNA in normal and carcinomatous tissues and showed higher levels of U6 snRNA in carcinoma tissues of human breast, liver, and intrahepatic bile ducts compared to normal adjacent tissues (Lou et al., Reference Lou, Ma, Xu, Jiang, Yang, Wang, Jiao and Gao2015). Therefore, the constancy of U6 snRNA expression should be ascertained prior to implementing its use as an endogenous reference control for qPCR normalization.

Exogenous reference genes

The use of exogenous mRNAs or DNAs added (‘spiked’) to specimens is well-described for qPCR normalization (Johnston et al., Reference Johnston, Gallaher and Czaja2012). Exogenous genes are often artificially synthesized and simultaneously detected by primers and probes distinct from those designed for the target genes. Unlike endogenous reference genes, they reflect variation in nucleic acid extraction and qPCR amplification procedures, but not sample collection and handling. For diagnostic qPCRs, exogenous reference genes provide the advantage of consistency, i.e. to avoid the variation reported for endogenous genes, and, therefore, may be a more reliable normalizer than endogenous genes. However, their use in gene expression research is limited because they do not provide a baseline for the comparison of treated and untreated subjects. Among animal qPCR publications reviewed, internal positive controls included in commercial qPCR assays were the most frequently used while heterologous genes, e.g. algal and enhanced green fluorescent genes, were described as well (Hoffmann et al., Reference Hoffmann, Depner, Schirrmeier and Beer2006; Henderson et al., Reference Henderson, Perkins, Havens, Kelly, Francis, Dole and Shek2013).

Use of endogenous and exogenous reference genes in routine oral fluid diagnostics

Exploration of the diagnostic use of PCR technologies for the detection of pathogen-specific nucleic acids in human oral fluids began in the 1990s (Mandel, Reference Mandel1993; Streckfus and Bigler, Reference Streckfus and Bigler2002) and early successes included Epstein–Barr virus, human herpesvirus type 6, HIV, human cytomegalovirus, and human papillomavirus (Goto et al., Reference Goto, Yeh, Notkins and Prabhakar1991; Saito et al., Reference Saito, Nishimura, Kudo, Fox and Moro1991; Garweg et al., Reference Garweg, Fenner, Bohnke and Schmitz1993; Tominaga et al., Reference Tominaga, FUKUSHIMA, Nishizaki, Watanabe, Masuda and Ogura1996). This developmental work led to PCR testing of oral fluid samples for the surveillance of human papillomavirus, HIV, measles, and others (Johnson et al., Reference Johnson, Parry, Best, Smith, De Silva and Mortimer1988; Frerichs et al., Reference Frerichs, Htoon, Eskes and Lwin1992; Ramsay et al., Reference Ramsay, Brugha and Brown1997; Ahn et al., Reference Ahn, Chan, Zhang, Wang, Khan, Bishop, Westra, Koch and Califano2014). More recently, SARS-CoV-2 has been detected in oral fluids, suggesting that oral fluid could facilitate the efficient surveillance of the ongoing worldwide coronavirus pandemic (COVID-19) (Azzi et al., Reference Azzi, Carcano, Gianfagna, Grossi, Dalla Gasperina, Genoni, Fasano, Sessa, Tettamanti, Carinci, Maurino, Rossi, Tagliabue and Baj2020; Pasomsub et al., Reference Pasomsub, Watcharananan, Boonyawat, Janchompoo, Wongtabtim, Suksuwan, Sungkanuparph and Phuphuakrat2020; To et al., Reference To, Tsang, Yip, Chan, Wu, Chan, Leung, Chik, Choi, Kandamby, Lung, Tam, Poon, Fung, Hung, Cheng, Chan and Yuen2020).

As for human beings, PCR technology has been applied to the detection of viral pathogens in animal oral fluid specimens, including feline herpesvirus 1 in oral swabs from experimentally inoculated cats (Reubel et al., Reference Reubel, Ramos, Hickman, Rimstad, Hoffmann and Pedersen1993), canine distemper virus in dogs (Shin et al., Reference Shin, Cho, Cho, Kang, Kim, Kim, Park and Park2004), Borna disease virus in rodents (Sierra-Honigmann et al., Reference Sierra-Honigmann, Rubin, Estafanous, Yolken and Carbone1993), FMDV in sheep (Callens et al., Reference Callens, De Clercq, Gruia and Danes1998), and PRRSV in swine (Wills et al., Reference Wills, Zimmerman, Yoon, Swenson, Mcginley, Hill, Platt, Christopher-Hennings and Nelson1997). As in human diagnostic medicine, PCR testing has been used in oral fluid-based surveillance and herd-level detection of various swine viral diseases, e.g. porcine circovirus type 2, PRRSV, porcine epidemic diarrhea virus, influenza A virus (Ramirez et al., Reference Ramirez, Wang, Prickett, Pogranichniy, Yoon, Main, Johnson, Rademacher, Hoogland, Hoffmann, Kurtz, Kurtz and Zimmerman2012; Bjustrom-Kraft et al., Reference Bjustrom-Kraft, Christopher-Hennings, Daly, Main, Torrison, Thurn and Zimmerman2018), and others (Henao-Diaz et al., Reference Henao-Diaz, Gimenez-Lirola, Baum and Zimmerman2020).

Several fundamental concerns arise when considering the routine use of endogenous reference genes in oral fluid specimens. First, oral fluid is not a cell-rich specimen and the quantity/concentration of target genes, e.g. viral DNA/RNA, may not be biologically associated with the concentration of endogenous reference genes, as it would in specimens with cellular context (Nybo, Reference Nybo2012). For that reason, endogenous reference genes commonly used with cell-rich specimens may not be valid for qPCR normalization in oral fluids. Second, the quality of oral fluid specimens can be affected by sample collection methods. Rogers et al. (Reference Rogers, Cole, Lan, Crossa and Demerath2007) reported that oral fluid specimens collected via spitting or oral rinse resulted in a higher concentration and quality of DNA compared to oral brush and swab samples (Rogers et al., Reference Rogers, Cole, Lan, Crossa and Demerath2007). Third, few studies have evaluated the expression of common endogenous reference genes in oral fluid specimens.

The ideal endogenous reference gene for the normalization of diagnostic qPCRs would be abundant and consistent across specimen types, stable in diagnostic specimens over time, and independent from the effect of the pathogen (or the treatment) on the host (Thellin et al., Reference Thellin, Zorzi, Lakaye, De Borman, Coumans, Hennen, Grisar, Igout and Heinen1999; Dheda et al., Reference Dheda, Huggett, Bustin, Johnson, Rook and Zumla2004; Radonic et al., Reference Radonic, Thulke, Mackay, Landt, Siegert and Nitsche2004; Mestdagh et al., Reference Mestdagh, Van Vlierberghe, De Weer, Muth, Westermann, Speleman and Vandesompele2009; Chervoneva et al., Reference Chervoneva, Li, Schulz, Croker, Wilson, Waldman and Hyslop2010). Such a reference gene has not been identified (Peltier and Latham, Reference Peltier and Latham2008); however, other genes inherent to oral fluid specimens merit consideration.

Ubiquitous in epithelial tissues throughout the body, mucins are a family of high molecular weight glycoproteins that are used to protect and lubricate mucosal surfaces (Gendler and Spicer, Reference Gendler and Spicer1995; Debailleul et al., Reference Debailleul, Laine, Huet, Mathon, D'hooghe, Aubert and Porchet1998; Moniaux et al., Reference Moniaux, Escande, Porchet, Aubert and Batra2001). The 21 types of mucin identified to date may be divided into gel-forming mucins, soluble mucins, and transmembrane mucins (Kumar et al., Reference Kumar, Cruz, Joshi, Patel, Jahan, Batra and Jain2017). Among these, MUC1, MUC4, MUC5B, MUC7, and MUC19 are secreted by salivary glands (Nielsen et al., Reference Nielsen, Bennett, Wandall, Therkildsen, Hannibal and Clausen1997; Thornton et al., Reference Thornton, Khan, Mehrotra, Howard, Veerman, Packer and Sheehan1999; Sengupta et al., Reference Sengupta, Valdramidou, Huntley, Hicks, Carrington and Corfield2001; Liu et al., Reference Liu, Lague, Nunes, Toselli, Oppenheim, Soares, Troxler and Offner2002; Alos et al., Reference Alos, Lujan, Castillo, Nadal, Carreras, Caballero, De Bolos and Cardesa2005; Linden et al., Reference Linden, Sutton, Karlsson, Korolik and Mcguckin2008), with MUC5B and MUC7, the two major mucins in saliva, constituting ~20% of the total salivary protein (Takehara et al., Reference Takehara, Yanagishita, Podyma-Inoue and Kawaguchi2013). Data are lacking at present, but future research should determine whether mRNAs that transcribe critical mucin domains might serve as endogenous reference standards for oral fluid specimens (Debailleul et al., Reference Debailleul, Laine, Huet, Mathon, D'hooghe, Aubert and Porchet1998).

As an alternative to a single endogenous reference gene, normalizing qPCR data against the geometric mean of multiple endogenous reference genes has been used in gene expression research. As opposed to using a single reference gene, this strategy lowers the risk of introducing additional variation into research data (Vandesompele et al., Reference Vandesompele, De Preter, Pattyn, Poppe, Van Roy, De Paepe and Speleman2002; Bustin et al., Reference Bustin, Benes, Garson, Hellemans, Huggett, Kubista, Mueller, Nolan, Pfaffl, Shipley, Vandesompele and Wittwer2009). For example, in a study comparing the mRNA levels of eight common endogenous reference genes in oral fluid specimens between healthy (n = 9) and autistic (n = 9) males (~4 years of age), the most consistent detection was determined in GAPDH mRNA, but the combination of GAPDH and YWHAZ (tyrosine 3-monooxygenase/tryptophan 5-monooxygenase activation protein and zeta polypeptide) mRNAs provided the best qPCR normalization (Panahi et al., Reference Panahi, Salasar Moghaddam, Ghasemi, Hadi Jafari, Shervin Badv, Eskandari and Pedram2016). Regardless, data normalization using multiple endogenous reference genes is impractical in high-throughput testing laboratories performing diagnostic qPCRs. For that reason, exogenously synthesized genetic sequences spiked into oral fluid samples have been utilized to monitor the DNA/RNA extraction and qPCR testing processes (Howson et al., Reference Howson, Armson, Lyons, Chepkwony, Kasanga, Kandusi, Ndusilo, Yamazaki, Gizaw, Cleaveland, Lembo, Rauh, Nelson, Wood, Mioulet, King and Fowler2018; Weiser et al., Reference Weiser, Poonsuk, Bade, Gauger, Rotolo, Harmon, Gonzalez, Wang, Main and Zimmerman2018; Nagel et al., Reference Nagel, Dimitrakopoulou, Teig, Kern, Lücke, Michna, Korn, Steininger, Shahada, Neumann and Überla2020; Nagura-Ikeda et al., Reference Nagura-Ikeda, Imai, Tabata, Miyoshi, Murahara, Mizuno, Horiuchi, Kato, Imoto, Iwata, Mimura, Ito, Tamura and Kato2020). Although they cannot reflect sample quality, exogenous reference genes can be used for qPCR normalization to provide consistent comparisons across clinical samples (Johnston et al., Reference Johnston, Gallaher and Czaja2012; O'Connell et al., Reference O'connell, Chantler and Barr2017).

Conclusion

Endogenous and exogenous reference genes are used in gene-expression studies to control for variation inherent in the qPCR testing process and achieve qPCR normalization using well-described mathematical approaches, e.g. the ΔC q method proposed by Pfaffl (Reference Pfaffl2001). Although qPCR normalization is recommended to ensure the comparability of results, the majority of oral fluid-based qPCR publications evaluated for this review (52.9% animal studies; 57.0% human studies) did not describe the use of internal controls (Table 1). As oral fluid-based PCRs become more widely implemented in human and veterinary diagnostic settings, this shortcoming should be addressed through the routine use of validated endogenous and/or exogenous reference genes in qPCR testing. The problems inherent with the use of endogenous reference genes include variation in the concentration of endogenous reference genes introduced by specimen matrices, sample quality and handling, subject age, animal species, and/or disease status (Bustin, Reference Bustin2002; Glare et al., Reference Glare, Divjak, Bailey and Walters2002; Bustin and Nolan, Reference Bustin and Nolan2004; Silver et al., Reference Silver, Best, Jiang and Thein2006; Nishimura et al., Reference Nishimura, Nikawa, Kawano, Nakayama and Ikeda2008; Kozera and Rapacz, Reference Kozera and Rapacz2013). One possible solution is to normalize qPCR data using two or more validated endogenous reference genes (Vandesompele et al., Reference Vandesompele, De Preter, Pattyn, Poppe, Van Roy, De Paepe and Speleman2002), but in the high-throughput diagnostic setting, a more efficient and practical approach would be spiking samples with a universally synthesized exogenous gene. Notably, this approach does not control for sample quality (Kavlick, Reference Kavlick2018). Finally, because of their robust and consistent expressions in oral fluids, specific mucin genes should be evaluated for the potential to serve as endogenous reference genes for qPCR normalization.

Conflict of interest

The authors declare no conflicts of interest with respect to their authorship and/or the publication of this manuscript.

References

Ahn, SM, Chan, JY, Zhang, Z, Wang, H, Khan, Z, Bishop, JA, Westra, W, Koch, WM and Califano, JA (2014) Saliva and plasma quantitative polymerase chain reaction-based detection and surveillance of human papillomavirus-related head and neck cancer. JAMA Otolaryngology – Head & Neck Surgery 140, 846854.CrossRefGoogle ScholarPubMed
Alfarouk, KO, Verduzco, D, Rauch, C, Muddathir, AK, Adil, HH, Elhassan, GO, Ibrahim, ME, David Polo Orozco, J, Cardone, RA, Reshkin, SJ and Harguindey, S (2014) Glycolysis, tumor metabolism, cancer growth and dissemination. A new pH-based etiopathogenic perspective and therapeutic approach to an old cancer question. Oncoscience 1, 777802.CrossRefGoogle Scholar
Alos, L, Lujan, B, Castillo, M, Nadal, A, Carreras, M, Caballero, M, De Bolos, C and Cardesa, A (2005) Expression of membrane-bound mucins (MUC1 and MUC4) and secreted mucins (MUC2, MUC5AC, MUC5B, MUC6 and MUC7) in mucoepidermoid carcinomas of salivary glands. American Journal of Surgical Pathology 29, 806813.CrossRefGoogle ScholarPubMed
Alshehhi, S and Haddrill, PR (2019) Estimating time since deposition using quantification of RNA degradation in body fluid-specific markers. Forensic Science International 298, 5863.CrossRefGoogle ScholarPubMed
Archibald, DW, Zon, L, Groopman, JE, Mclane, MF and Essex, M (1986) Antibodies to human T-lymphotropic virus type-III (HTLV-III) in saliva of acquired-immunodeficiency-syndrome (AIDS) patients and in persons at risk for AIDS. Blood 67, 831834.CrossRefGoogle ScholarPubMed
Atkinson, JC, Dawes, C, Ericson, T, Fox, PC, Gandara, BK, Malamud, D, Mandel, ID, Navazesh, M and Tabak, LA (1993). Guidelines for Saliva Nomenclature and Collection. Annals of the New York Academy of Sciences 694, xixii.Google Scholar
Azzi, L, Carcano, G, Gianfagna, F, Grossi, P, Dalla Gasperina, D, Genoni, A, Fasano, M, Sessa, F, Tettamanti, L, Carinci, F, Maurino, V, Rossi, A, Tagliabue, A and Baj, A (2020) Saliva is a reliable tool to detect SARS-CoV-2. Journal of Infection 81, E45E50.CrossRefGoogle ScholarPubMed
Ban, N, Beckmann, R, Cate, JH, Dinman, JD, Dragon, F, Ellis, SR, Lafontaine, DL, Lindahl, L, Liljas, A, Lipton, JM, Mcalear, MA, Moore, PB, Noller, HF, Ortega, J, Panse, VG, Ramakrishnan, V, Spahn, CM, Steitz, TA, Tchorzewski, M, Tollervey, D, Warren, AJ, Williamson, JR, Wilson, D, Yonath, A and Yusupov, M (2014) A new system for naming ribosomal proteins. Current Opinion in Structural Biology 24, 165169.CrossRefGoogle ScholarPubMed
Bar, M, Bar, D and Lehmann, B (2009) Selection and validation of candidate housekeeping genes for studies of human keratinocytes – review and recommendations. Journal of Investigative Dermatology 129, 535537.CrossRefGoogle ScholarPubMed
Barber, RD, Harmer, DW, Coleman, RA and Clark, BJ (2005) GAPDH as a housekeeping gene: analysis of GAPDH mRNA expression in a panel of 72 human tissues. Physiological Genomics 21, 389395.CrossRefGoogle Scholar
Basso, D, Aita, A, Navaglia, F, Franchin, E, Fioretto, P, Moz, S, Bozzato, D, Zambon, CF, Martin, B, Dal Pra, C, Crisanti, A and Plebani, M (2020) SARS-CoV-2 RNA identification in nasopharyngeal swabs: issues in pre-analytics. Clinical Chemistry and Laboratory Medicine 58, 15791586.CrossRefGoogle ScholarPubMed
Becker, C, Hammerle-Fickinger, A, Riedmaier, I and Pfaffl, MW (2010) mRNA and microRNA quality control for RT-qPCR analysis. Methods (San Diego, Calif.) 50, 237243.CrossRefGoogle ScholarPubMed
Biassoni, R and Raso, A (2014) Quantitative Real-Time PCR: Methods and Protocols. New York: Springer.CrossRefGoogle Scholar
Biederman, J, Yee, J and Cortes, P (2004) Validation of internal control genes for gene expression analysis in diabetic glomerulosclerosis. Kidney International 66, 23082314.CrossRefGoogle ScholarPubMed
Bjustrom-Kraft, J, Christopher-Hennings, J, Daly, R, Main, R, Torrison, J, Thurn, M and Zimmerman, J (2018) The use of oral fluid diagnostics in swine medicine. Journal of Swine Health and Production 26, 262269.Google Scholar
Bonaldo, MC, Ribeiro, IP, Lima, NS, Dos Santos, AA, Menezes, LS, Da Cruz, SO, De Mello, IS, Furtado, ND, De Moura, EE, Damasceno, L, Da Silva, KA, De Castro, MG, Gerber, AL, De Almeida, LG, Lourenco-De-Oliveira, R, Vasconcelos, AT and Brasil, P (2016) Isolation of infective Zika virus from urine and saliva of patients in Brazil. PLoS Neglected Tropical Diseases 10, e0004816.CrossRefGoogle ScholarPubMed
Brow, DA and Guthrie, C (1988) Spliceosomal RNA U6 is remarkably conserved from yeast to mammals. Nature 334, 213218.CrossRefGoogle ScholarPubMed
Bunnell, TM, Burbach, BJ, Shimizu, Y and Ervasti, JM (2011) Beta-actin specifically controls cell growth, migration, and the G-actin pool. Molecular Biology of the Cell 22, 40474058.CrossRefGoogle ScholarPubMed
Bushati, N and Cohen, SM (2007) microRNA functions. Annual Review of Cell and Developmental Biology 23, 175205.CrossRefGoogle ScholarPubMed
Bustin, SA (2002) Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems. Journal of Molecular Endocrinology 29, 2339.CrossRefGoogle ScholarPubMed
Bustin, SA and Nolan, T (2004) Pitfalls of quantitative real-time reverse-transcription polymerase chain reaction. Journal of Biomolecular Techniques: JBT 15, 155166.Google ScholarPubMed
Bustin, SA, Benes, V, Nolan, T and Pfaffl, MW (2005) Quantitative real-time RT-PCR – a perspective. Journal of Molecular Endocrinology 34, 597601.CrossRefGoogle ScholarPubMed
Bustin, SA, Benes, V, Garson, JA, Hellemans, J, Huggett, J, Kubista, M, Mueller, R, Nolan, T, Pfaffl, MW, Shipley, GL, Vandesompele, J and Wittwer, CT (2009) The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. Clinical Chemistry 55, 611622.CrossRefGoogle ScholarPubMed
Bylesjö, M, Cloarec, O and Rantalainen, M (2009) Normalization and closure. In: Brown, SD, Tauler, R and Walczak, B (eds.) Comprehensive Chemometrics : Chemical and Biochemical Data Analysis. Amsterdam: Elsevier, pp. A109A127.CrossRefGoogle Scholar
Callens, M, De Clercq, K, Gruia, M and Danes, M (1998) Detection of foot-and-mouth disease by reverse transcription polymerase chain reaction and virus isolation in contact sheep without clinical signs of foot-and-mouth disease. Veterinary Quarterly 20, 3740.CrossRefGoogle ScholarPubMed
Cavalcante, LTF, Muniz, CP, Jia, H, Augusto, AM, Troccoli, F, Medeiros, SO, Dias, CGA, Switzer, WM, Soares, MA and Santos, AF (2018) Clinical and molecular features of feline foamy virus and feline leukemia virus co-infection in naturally-infected cats. Viruses 10, 702.CrossRefGoogle ScholarPubMed
Cheng, TY, Buckley, A, Van Geelen, A, Lager, K, Henao-Diaz, A, Poonsuk, K, Pineyro, P, Baum, D, Ji, J, Wang, C, Main, R, Zimmerman, J and Gimenez-Lirola, L (2020) Detection of pseudorabies virus antibody in swine oral fluid using a serum whole-virus indirect ELISA. Journal of Veterinary Diagnostic Investigation 32, 535541.CrossRefGoogle ScholarPubMed
Chervoneva, I, Li, Y, Schulz, S, Croker, S, Wilson, C, Waldman, SA and Hyslop, T (2010) Selection of optimal reference genes for normalization in quantitative RT-PCR. BMC Bioinformatics 11, 253.CrossRefGoogle ScholarPubMed
Cone, EJ and Huestis, MA (2007) Interpretation of oral fluid tests for drugs of abuse. Annals of the New York Academy of Sciences 1098, 51103.CrossRefGoogle ScholarPubMed
Crouch, DJ (2005) Oral fluid collection: the neglected variable in oral fluid testing. Forensic Science International 150, 165173.CrossRefGoogle ScholarPubMed
Dahdouh, E, Lazaro-Perona, F, Romero-Gomez, MP, Mingorance, J and Garcia-Rodriguez, J (2021). Ct values from SARS-CoV-2 diagnostic PCR assays should not be used as direct estimates of viral load. J Infect 82, 414451.CrossRefGoogle Scholar
Debailleul, V, Laine, A, Huet, G, Mathon, P, D'hooghe, MC, Aubert, JP and Porchet, N (1998) Human mucin genes MUC2, MUC3, MUC4, MUC5AC, MUC5B, and MUC6 express stable and extremely large mRNAs and exhibit a variable length polymorphism. An improved method to analyze large mRNAs. Journal of Biological Chemistry 273, 881890.CrossRefGoogle ScholarPubMed
Deindl, E, Boengler, K, Van Royen, N and Schaper, W (2002) Differential expression of GAPDH and beta3-actin in growing collateral arteries. Molecular and Cellular Biochemistry 236, 139146.CrossRefGoogle ScholarPubMed
De Ketelaere, A, Goossens, K, Peelman, L and Burvenich, C (2006) Technical note: Validation of internal control genes for gene expression analysis in bovine polymorphonuclear leukocytes. Journal of Dairy Science 89, 40664069.CrossRefGoogle ScholarPubMed
Detmer, SE, Patnayak, DP, Jiang, Y, Gramer, MR and Goyal, SM (2011) Detection of influenza A virus in porcine oral fluid samples. Journal of Veterinary Diagnostic Investigation 23, 241247.CrossRefGoogle ScholarPubMed
Dheda, K, Huggett, JF, Bustin, SA, Johnson, MA, Rook, G and Zumla, A (2004) Validation of housekeeping genes for normalizing RNA expression in real-time PCR. Biotechniques 37, 112114, 116, 118–119.CrossRefGoogle ScholarPubMed
Didychuk, AL, Butcher, SE and Brow, DA (2018) The life of U6 small nuclear RNA, from cradle to grave. RNA 24, 437460.CrossRefGoogle ScholarPubMed
Die, JV, Baldwin, RL, Rowland, LJ, Li, R, Oh, S, Li, C, Connor, EE and Ranilla, MJ (2017) Selection of internal reference genes for normalization of reverse transcription quantitative polymerase chain reaction (RT-qPCR) analysis in the rumen epithelium. PLoS One 12, e0172674.CrossRefGoogle ScholarPubMed
Dietze, K, Moritz, T, Alexandrov, T, Krstevski, K, Schlottau, K, Milovanovic, M, Hoffmann, D and Hoffmann, B (2018) Suitability of group-level oral fluid sampling in ruminant populations for lumpy skin disease virus detection. Veterinary Microbiology 221, 4448.CrossRefGoogle ScholarPubMed
Douglas, RG Jr. and Couch, RB (1970) A prospective study of chronic herpes simplex virus infection and recurrent herpes labialis in humans. Journal of Immunology 104, 289295.CrossRefGoogle ScholarPubMed
Duan, ZY, Cai, GY, Li, JJ, Bu, R, Wang, N, Yin, P and Chen, XM (2018) U6 can be used as a housekeeping gene for urinary sediment miRNA studies of IgA nephropathy. Scientific Reports 8, 10875.CrossRefGoogle ScholarPubMed
Dube, S, Qin, J and Ramakrishnan, R (2008) Mathematical analysis of copy number variation in a DNA sample using digital PCR on a nanofluidic device. PLoS One 3, e2876.CrossRefGoogle Scholar
Duffy, CE, Woolley, PV Jr. and Nolting, WS (1947). Rabies; a case report with notes on the isolation of the virus from saliva. The Journal of Pediatrics 31, 440447.CrossRefGoogle ScholarPubMed
Filzmoser, P and Walczak, B (2014) What can go wrong at the data normalization step for identification of biomarkers? Journal of Chromatography A 1362, 194205.CrossRefGoogle ScholarPubMed
Frerichs, RR, Htoon, MT, Eskes, N and Lwin, S (1992) Comparison of saliva and serum for HIV surveillance in developing countries. Lancet (London, England) 340, 14961499.CrossRefGoogle ScholarPubMed
Garrett, JR (1975) Changing attitudes on salivary secretion – a short history on spit. Proceedings of the Royal Society of Medicine 68, 553560.CrossRefGoogle Scholar
Garweg, J, Fenner, T, Bohnke, M and Schmitz, H (1993) An improved technique for the diagnosis of viral retinitis from samples of aqueous humor and vitreous. Graefe's Archive for Clinical and Experimental Ophthalmology 231, 508513.CrossRefGoogle ScholarPubMed
Gendler, SJ and Spicer, AP (1995) Epithelial mucin genes. Annual Review of Physiology 57, 607634.CrossRefGoogle ScholarPubMed
Glare, EM, Divjak, M, Bailey, MJ and Walters, EH (2002) Beta-actin and GAPDH housekeeping gene expression in asthmatic airways is variable and not suitable for normalising mRNA levels. Thorax 57, 765770.CrossRefGoogle Scholar
Gomes-Keller, MA, Gonczi, E, Tandon, R, Riondato, F, Hofmann-Lehmann, R, Meli, ML and Lutz, H (2006) Detection of feline leukemia virus RNA in saliva from naturally infected cats and correlation of PCR results with those of current diagnostic methods. Journal of Clinical Microbiology 44, 916922.CrossRefGoogle ScholarPubMed
Goto, Y, Yeh, CK, Notkins, AL and Prabhakar, BS (1991) Detection of proviral sequences in saliva of patients infected with human immunodeficiency virus type 1. AIDS Research and Human Retroviruses 7, 343347.CrossRefGoogle ScholarPubMed
Green, MR and Sambrook, J (2012). Isolation and Quantification of DNA. In: Green, MR and Sambrook, J (eds.) Molecular Cloning: A Laboratory Manual. 4 ed. Cold Spring Harbor, NY: Cold Spring Harbor Laboratory Press, pp. 1180.Google Scholar
Groopman, JE, Salahuddin, SZ, Sarngadharan, MG, Markham, PD, Gonda, M, Sliski, A and Gallo, RC (1984) HTLV-III in saliva of people with AIDS-related complex and healthy homosexual men at risk for AIDS. Science (New York, N.Y.) 226, 447449.CrossRefGoogle ScholarPubMed
Guenin, S, Mauriat, M, Pelloux, J, Van Wuytswinkel, O, Bellini, C and Gutierrez, L (2009) Normalization of qRT-PCR data: the necessity of adopting a systematic, experimental conditions-specific, validation of references. Journal of Experimental Botany 60, 487493.CrossRefGoogle ScholarPubMed
Gutala, RV and Reddy, PH (2004) The use of real-time PCR analysis in a gene expression study of Alzheimer's disease post-mortem brains. Journal of Neuroscience Methods 132, 101107.CrossRefGoogle Scholar
Hamalainen, HK, Tubman, JC, Vikman, S, Kyrola, T, Ylikoski, E, Warrington, JA and Lahesmaa, R (2001) Identification and validation of endogenous reference genes for expression profiling of T helper cell differentiation by quantitative real-time RT-PCR. Analytical Biochemistry 299, 6370.CrossRefGoogle ScholarPubMed
Heid, CA, Stevens, J, Livak, KJ and Williams, PM (1996) Real time quantitative PCR. Genome Research 6, 986994.CrossRefGoogle ScholarPubMed
Henao-Diaz, A, Gimenez-Lirola, L, Baum, DH and Zimmerman, J (2020). Guidelines for oral fluid-based surveillance of viral pathogens in swine. Porcine Health Manag, 6, 28.CrossRefGoogle ScholarPubMed
Henderson, KS, Perkins, CL, Havens, RB, Kelly, MJ, Francis, BC, Dole, VS and Shek, WR (2013) Efficacy of direct detection of pathogens in naturally infected mice by using a high-density PCR array. Journal of the American Association for Laboratory Animal Science 52, 763772.Google ScholarPubMed
Henle, G, Henle, W, Wendell, KK and Rosenberg, P (1948). Isolation of mumps virus from human beings with induced apparent or inapparent infections. J Exp Med 88, 223–32.CrossRefGoogle ScholarPubMed
Hoffmann, B, Depner, K, Schirrmeier, H and Beer, M (2006) A universal heterologous internal control system for duplex real-time RT-PCR assays used in a detection system for pestiviruses. Journal of Virological Methods 136, 200209.CrossRefGoogle Scholar
Hoorfar, J, Malorny, B, Abdulmawjood, A, Cook, N, Wagner, M and Fach, P (2004) Practical considerations in design of internal amplification controls for diagnostic PCR assays. Journal of Clinical Microbiology 42, 18631868.CrossRefGoogle ScholarPubMed
Howson, ELA, Armson, B, Lyons, NA, Chepkwony, E, Kasanga, CJ, Kandusi, S, Ndusilo, N, Yamazaki, W, Gizaw, D, Cleaveland, S, Lembo, T, Rauh, R, Nelson, WM, Wood, BA, Mioulet, V, King, DP and Fowler, VL (2018) Direct detection and characterization of foot-and-mouth disease virus in East Africa using a field-ready real-time PCR platform. Transboundary and Emerging Diseases 65, 221231.CrossRefGoogle ScholarPubMed
Huggett, J, Dheda, K, Bustin, S and Zumla, A (2005) Real-time RT-PCR normalisation; strategies and considerations. Genes and Immunity 6, 279284.CrossRefGoogle ScholarPubMed
Huggett, JF, Foy, CA, Benes, V, Emslie, K, Garson, JA, Haynes, R, Hellemans, J, Kubista, M, Mueller, RD and Nolan, T (2013) The digital MIQE guidelines: minimum information for publication of quantitative digital PCR experiments. Clinical Chemistry 59, 892902.CrossRefGoogle ScholarPubMed
Hunter, T and Garrels, JI (1977) Characterization of the mRNAs for alpha-, beta- and gamma-actin. Cell 12, 767781.CrossRefGoogle ScholarPubMed
Ingerslev, HC, Pettersen, EF, Jakobsen, RA, Petersen, CB and Wergeland, HI (2006). Expression profiling and validation of reference gene candidates in immune relevant tissues and cells from Atlantic salmon (Salmo salar L.). Molecular Immunology, 43, 11941201.CrossRefGoogle ScholarPubMed
Johansson, S, Fuchs, A, Okvist, A, Karimi, M, Harper, C, Garrick, T, Sheedy, D, Hurd, Y, Bakalkin, G and Ekstrom, TJ (2007) Validation of endogenous controls for quantitative gene expression analysis: application on brain cortices of human chronic alcoholics. Brain Research 1132, 2028.CrossRefGoogle ScholarPubMed
Johnson, CD and Goodpasture, EW (1934) An investigation of the etiology of mumps. Journal of Experimental Medicine 59, 119.CrossRefGoogle ScholarPubMed
Johnson, AM, Parry, JV, Best, SJ, Smith, AM, De Silva, M and Mortimer, PP (1988) HIV surveillance by testing saliva. AIDS (London, England) 2, 369371.CrossRefGoogle ScholarPubMed
Johnson, G, Nolan, T and Bustin, SA (2013). Real-time quantitative PCR, pathogen detection and MIQE. In: Wilks, M (ed.) PCR detection of microbial pathogens. Totowa, New Jersey: Humana Press. 116.Google Scholar
Johnston, S, Gallaher, Z and Czaja, K (2012) Exogenous reference gene normalization for real-time reverse transcription-polymerase chain reaction analysis under dynamic endogenous transcription. Neural Regeneration Research 7, 10641072.Google ScholarPubMed
Jones, LJ, Yue, ST, Cheung, CY and Singer, VL (1998) RNA quantitation by fluorescence-based solution assay: riboGreen reagent characterization. Analytical Biochemistry 265, 368374.CrossRefGoogle ScholarPubMed
Jursza, E, Skarzynski, DJ and Siemieniuch, MJ (2014) Validation of reference genes in the feline endometrium. Reproductive Biology 14, 302306.CrossRefGoogle ScholarPubMed
Kaufman, HE, Brown, DC and Ellison, EM (1967) Recurrent herpes in the rabbit and man. Science (New York, N.Y.) 156, 16281629.CrossRefGoogle ScholarPubMed
Kavlick, MF (2018) Development of a universal internal positive control. Biotechniques 65, 275280.CrossRefGoogle ScholarPubMed
Ke, LD, Chen, Z and Yung, WK (2000) A reliability test of standard-based quantitative PCR: exogenous vs endogenous standards. Molecular and Cellular Probes 14, 127135.CrossRefGoogle ScholarPubMed
Kessler, Y, Helfer-Hungerbuehler, AK, Cattori, V, Meli, ML, Zellweger, B, Ossent, P, Riond, B, Reusch, CE, Lutz, H and Hofmann-Lehmann, R (2009) Quantitative TaqMan (R) real-time PCR assays for gene expression normalisation in feline tissues. BMC Molecular Biology 10, 106.CrossRefGoogle Scholar
Khanna, P, Johnson, KL and Maron, JL (2017) Optimal reference genes for RT-qPCR normalization in the newborn. Biotechnic and Histochemistry 92, 459466.CrossRefGoogle ScholarPubMed
Kintz, P, Cirimele, V and Ludes, B (2000) Detection of cannabis in oral fluid (saliva) and forehead wipes (sweat) from impaired drivers. Journal of Analytical Toxicology 24, 557561.CrossRefGoogle ScholarPubMed
Klein, D (2002) Quantification using real-time PCR technology: applications and limitations. Trends in Molecular Medicine 8, 257260.CrossRefGoogle ScholarPubMed
Koppelkamm, A, Vennemann, B, Fracasso, T, Lutz-Bonengel, S, Schmidt, U and Heinrich, M (2010) Validation of adequate endogenous reference genes for the normalisation of qPCR gene expression data in human post mortem tissue. International Journal of Legal Medicine 124, 371380.CrossRefGoogle ScholarPubMed
Kozera, B and Rapacz, M (2013) Reference genes in real-time PCR. Journal of Applied Genetics 54, 391406.CrossRefGoogle ScholarPubMed
Kralik, P and Ricchi, M (2017) A basic guide to real time PCR in microbial diagnostics: definitions, parameters, and everything. Frontiers in Microbiology 8, 108.CrossRefGoogle ScholarPubMed
Kumar, S, Cruz, E, Joshi, S, Patel, A, Jahan, R, Batra, SK and Jain, M (2017) Genetic variants of mucins: unexplored conundrum. Carcinogenesis 38, 671679.Google ScholarPubMed
Lafontaine, DL and Tollervey, D (2001) The function and synthesis of ribosomes. Nature Reviews Molecular Cell Biology 2, 514520.CrossRefGoogle ScholarPubMed
Larghi, OP, Nebel, AE, Lazaro, L and Savy, VL (1975) Sensitivity of BHK-21 cells supplemented with diethylaminoethyl-dextran for detection of street rabies virus in saliva samples. Journal of Clinical Microbiology 1, 243245.CrossRefGoogle ScholarPubMed
Linden, SK, Sutton, P, Karlsson, NG, Korolik, V and Mcguckin, MA (2008) Mucins in the mucosal barrier to infection. Mucosal Immunology 1, 183197.CrossRefGoogle ScholarPubMed
Liu, W and Saint, DA (2002) A new quantitative method of real time reverse transcription polymerase chain reaction assay based on simulation of polymerase chain reaction kinetics. Analytical Biochemistry 302, 5259.CrossRefGoogle ScholarPubMed
Liu, B, Lague, JR, Nunes, DP, Toselli, P, Oppenheim, FG, Soares, RV, Troxler, RF and Offner, GD (2002) Expression of membrane-associated mucins MUC1 and MUC4 in major human salivary glands. Journal of Histochemistry and Cytochemistry 50, 811820.CrossRefGoogle ScholarPubMed
Livak, KJ and Schmittgen, TD (2001) Analysis of relative gene expression data using real-time quantitative PCR and the 2(-Delta Delta C(T)) method. Methods (San Diego, Calif.) 25, 402408.CrossRefGoogle ScholarPubMed
Lou, G, Ma, N, Xu, Y, Jiang, L, Yang, J, Wang, C, Jiao, Y and Gao, X (2015) Differential distribution of U6 (RNU6-1) expression in human carcinoma tissues demonstrates the requirement for caution in the internal control gene selection for microRNA quantification. International Journal of Molecular Medicine 36, 14001408.CrossRefGoogle ScholarPubMed
Lutz, CK, Tiefenbacher, S, Jorgensen, MJ, Meyer, JS and Novak, MA (2000) Techniques for collecting saliva from awake, unrestrained, adult monkeys for cortisol assay. American Journal of Primatology 52, 9399.3.0.CO;2-B>CrossRefGoogle ScholarPubMed
Madonia, JV, Bahn, AN and Calandra, JC (1966) Salivary excretion of Coxsackie b-1 virus in rabbits. Applied Microbiology 14, 394396.CrossRefGoogle ScholarPubMed
Mandel, ID (1993) A contemporary view of salivary research. Critical Reviews in Oral Biology & Medicine 4, 599604.CrossRefGoogle ScholarPubMed
Maniatis, T and Reed, R (1987) The role of small nuclear ribonucleoprotein particles in pre-mRNA splicing. Nature 325, 673678.CrossRefGoogle ScholarPubMed
Maron, JL, Johnson, KL, Dietz, JA, Chen, ML and Bianchi, DW (2012) Neuropeptide Y2 receptor (NPY2R) expression in saliva predicts feeding immaturity in the premature neonate. PLoS One 7, e37870.CrossRefGoogle ScholarPubMed
Martin, JL (2016) Validation of reference genes for oral cancer detection panels in a prospective blinded cohort. PLoS One 11, e0158462.CrossRefGoogle Scholar
Mase, M, Grasso, M, Avogaro, L, D'amato, E, Tessarolo, F, Graffigna, A, Denti, MA and Ravelli, F (2017) Selection of reference genes is critical for miRNA expression analysis in human cardiac tissue. A focus on atrial fibrillation. Scientific Reports 7, 41127.CrossRefGoogle Scholar
Mcintosh, KA, Tumber, A, Harding, JCS, Krakowka, S, Ellis, JA and Hill, JE (2009) Development and validation of a SYBR green real-time PCR for the quantification of porcine circovirus type 2 in serum, buffy coat, feces, and multiple tissues. Veterinary Microbiology 133, 2333.CrossRefGoogle ScholarPubMed
Mestdagh, P, Van Vlierberghe, P, De Weer, A, Muth, D, Westermann, F, Speleman, F and Vandesompele, J (2009) A novel and universal method for microRNA RT-qPCR data normalization. Genome Biology 10, R64.CrossRefGoogle ScholarPubMed
Moniaux, N, Escande, F, Porchet, N, Aubert, JP and Batra, SK (2001) Structural organization and classification of the human mucin genes. Frontiers in Bioscience 6, D1192D1206.CrossRefGoogle ScholarPubMed
Moore, MJ and Proudfoot, NJ (2009) Pre-mRNA processing reaches back to transcription and ahead to translation. Cell 136, 688700.CrossRefGoogle ScholarPubMed
Nagel, A, Dimitrakopoulou, E, Teig, N, Kern, P, Lücke, T, Michna, D, Korn, K, Steininger, P, Shahada, K, Neumann, K and Überla, K (2020) Characterization of a universal screening approach for congenital CMV infection based on a highly-sensitive, quantitative, multiplex real-time PCR assay. PLoS One 15, e0227143.CrossRefGoogle ScholarPubMed
Nagura-Ikeda, M, Imai, K, Tabata, S, Miyoshi, K, Murahara, N, Mizuno, T, Horiuchi, M, Kato, K, Imoto, Y, Iwata, M, Mimura, S, Ito, T, Tamura, K and Kato, Y (2020). Clinical Evaluation of Self-Collected Saliva by Quantitative Reverse Transcription-PCR (RT-qPCR), Direct RT-qPCR, Reverse Transcription-Loop-Mediated Isothermal Amplification, and a Rapid Antigen Test To Diagnose COVID-19. J Clin Microbiol, 58, e01438–20.CrossRefGoogle Scholar
Nicholls, C, Li, H and Liu, JP (2012) GAPDH: a common enzyme with uncommon functions. Clinical and Experimental Pharmacology and Physiology 39, 674679.CrossRefGoogle ScholarPubMed
Nielsen, PA, Bennett, EP, Wandall, HH, Therkildsen, MH, Hannibal, J and Clausen, H (1997) Identification of a major human high molecular weight salivary mucin (MG1) as tracheobronchial mucin MUC5B. Glycobiology 7, 413419.CrossRefGoogle Scholar
Nishimura, M, Nikawa, T, Kawano, Y, Nakayama, M and Ikeda, M (2008) Effects of dimethyl sulfoxide and dexamethasone on mRNA expression of housekeeping genes in cultures of C2C12 myotubes. Biochemical and Biophysical Research Communications 367, 603608.CrossRefGoogle ScholarPubMed
Nybo, K (2012) qRT-PCR with saliva samples. Biotechniques 53, 137138.CrossRefGoogle ScholarPubMed
O'connell, GC, Chantler, PD and Barr, TL (2017) High interspecimen variability in nucleic acid extraction efficiency necessitates the use of spike-in control for accurate qPCR-based measurement of plasma cell-free DNA levels. Laboratory Medicine 48, 332338.CrossRefGoogle ScholarPubMed
Palmer, MV, Whipple, DL and Waters, WR (2001) Experimental deer-to-deer transmission of Mycobacterium bovis. American Journal of Veterinary Research 62, 692696.CrossRefGoogle ScholarPubMed
Panahi, Y, Salasar Moghaddam, F, Ghasemi, Z, Hadi Jafari, M, Shervin Badv, R, Eskandari, MR and Pedram, M (2016) Selection of suitable reference genes for analysis of salivary transcriptome in non-syndromic autistic male children. International Journal of Molecular Sciences 17, 1711.CrossRefGoogle ScholarPubMed
Pasomsub, E, Watcharananan, SP, Boonyawat, K, Janchompoo, P, Wongtabtim, G, Suksuwan, W, Sungkanuparph, S and Phuphuakrat, A (2021). Saliva sample as a non-invasive specimen for the diagnosis of coronavirus disease 2019: a cross-sectional study. Clin Microbiol Infect 27, 285 e1285 e4.CrossRefGoogle ScholarPubMed
Peltier, HJ and Latham, GJ (2008) Normalization of microRNA expression levels in quantitative RT-PCR assays: identification of suitable reference RNA targets in normal and cancerous human solid tissues. RNA 14, 844852.CrossRefGoogle ScholarPubMed
Peters, IR, Peeters, D, Helps, CR and Day, MJ (2007) Development and application of multiple internal reference (housekeeper) gene assays for accurate normalisation of canine gene expression studies. Veterinary Immunology and Immunopathology 117, 5566.CrossRefGoogle ScholarPubMed
Pfaffl, MW (2001) A new mathematical model for relative quantification in real-time RT-PCR. Nucleic Acids Research 29, e45.CrossRefGoogle ScholarPubMed
Pol, F, Deblanc, C, Oger, A, Le Dimna, M, Simon, G and Le Potier, MF (2013) Validation of a commercial real-time PCR kit for specific and sensitive detection of pseudorabies. Journal of Virological Methods 187, 421423.CrossRefGoogle ScholarPubMed
Prickett, JR, Kim, W, Simer, R, Yoon, KJ and Zimmerman, J (2008) Oral-fluid samples for surveillance of commercial growing pigs for porcine reproductive and respiratory syndrome virus and porcine circovirus type 2 infections. Journal of Swine Health and Production 16, 8691.Google Scholar
Radonic, A, Thulke, S, Mackay, IM, Landt, O, Siegert, W and Nitsche, A (2004) Guideline to reference gene selection for quantitative real-time PCR. Biochemical and Biophysical Research Communications 313, 856862.CrossRefGoogle ScholarPubMed
Ramirez, A, Wang, C, Prickett, JR, Pogranichniy, R, Yoon, KJ, Main, R, Johnson, JK, Rademacher, C, Hoogland, M, Hoffmann, P, Kurtz, A, Kurtz, E and Zimmerman, J (2012) Efficient surveillance of pig populations using oral fluids. Preventive Veterinary Medicine 104, 292300.CrossRefGoogle ScholarPubMed
Ramsay, M, Brugha, R and Brown, D (1997) Surveillance of measles in England and Wales: implications of a national saliva testing programme. Bulletin of the World Health Organization 75, 515521.Google ScholarPubMed
Rao, X, Huang, X, Zhou, Z and Lin, X (2013) An improvement of the 2^(-delta delta CT) method for quantitative real-time polymerase chain reaction data analysis. Biostatistics, Bioinformatics and Biomathematics 3, 7185.Google ScholarPubMed
Rebouças, EDL, Costa, JJDN, Passos, MJ, Passos, JRDS, Hurk, RVD and Silva, JRV (2013) Real time PCR and importance of housekeepings genes for normalization and quantification of mRNA expression in different tissues. Brazilian Archives of Biology and Technology 56, 143154.CrossRefGoogle Scholar
Rekawiecki, R, Kowalik, MK and Kotwica, J (2013) Validation of housekeeping genes for studying differential gene expression in the bovine myometrium. Acta Veterinaria Hungarica 61, 505516.CrossRefGoogle ScholarPubMed
Reubel, GH, Ramos, RA, Hickman, MA, Rimstad, E, Hoffmann, DE and Pedersen, NC (1993) Detection of active and latent feline herpesvirus-1 infections using the polymerase chain-reaction. Archives of Virology 132, 409420.CrossRefGoogle ScholarPubMed
Robinson, TL, Sutherland, IA and Sutherland, J (2007) Validation of candidate bovine reference genes for use with real-time PCR. Veterinary Immunology and Immunopathology 115, 160165.CrossRefGoogle ScholarPubMed
Rogers, NL, Cole, SA, Lan, HC, Crossa, A and Demerath, EW (2007) New saliva DNA collection method compared to buccal cell collection techniques for epidemiological studies. American Journal of Human Biology 19, 319326.CrossRefGoogle ScholarPubMed
Ruan, W and Lai, M (2007) Actin, a reliable marker of internal control? Clinica Chimica Acta 385, 15.CrossRefGoogle ScholarPubMed
Saito, I, Nishimura, S, Kudo, I, Fox, RI and Moro, I (1991) Detection of Epstein–Barr virus and human herpes virus type 6 in saliva from patients with lymphoproliferative diseases by the polymerase chain reaction. Archives of Oral Biology 36, 779784.CrossRefGoogle ScholarPubMed
Schmittgen, TD and Livak, KJ (2008) Analyzing real-time PCR data by the comparative C(T) method. Nature Protocols 3, 11011108.CrossRefGoogle ScholarPubMed
Schramm, W, Smith, RH and Craig, PA (1993) Methods of simplified saliva collection for the measurement of drugs of abuse, therapeutic drugs, and other molecules. Annals of the New York Academy of Sciences 694, 311313.CrossRefGoogle ScholarPubMed
Schroeder, A, Mueller, O, Stocker, S, Salowsky, R, Leiber, M, Gassmann, M, Lightfoot, S, Menzel, W, Granzow, M and Ragg, T (2006) The RIN: an RNA integrity number for assigning integrity values to RNA measurements. BMC Molecular Biology 7, 3.CrossRefGoogle ScholarPubMed
Sellers, RF, Burrows, R, Mann, JA and Dawe, P (1968) Recovery of virus from bulls affected with foot-and-mouth disease. The Veterinary Record 83, 303.CrossRefGoogle ScholarPubMed
Selvey, S, Thompson, EW, Matthaei, K, Lea, RA, Irving, MG and Griffiths, LR (2001) Beta-actin – an unsuitable internal control for RT-PCR. Molecular and Cellular Probes 15, 307311.CrossRefGoogle ScholarPubMed
Sengupta, A, Valdramidou, D, Huntley, S, Hicks, SJ, Carrington, SD and Corfield, AP (2001) Distribution of MUC1 in the normal human oral cavity is localized to the ducts of minor salivary glands. Archives of Oral Biology 46, 529538.CrossRefGoogle Scholar
Sergiev, PV, Aleksashin, NA, Chugunova, AA, Polikanov, YS and Dontsova, OA (2018) Structural and evolutionary insights into ribosomal RNA methylation. Nature Chemical Biology 14, 226235.CrossRefGoogle ScholarPubMed
Shen, Y, Li, Y, Ye, F, Wang, F, Lu, W and Xie, X (2010) Identification of suitable reference genes for measurement of gene expression in human cervical tissues. Analytical Biochemistry 405, 224229.CrossRefGoogle ScholarPubMed
Shin, YJ, Cho, KO, Cho, HS, Kang, SK, Kim, HJ, Kim, YH, Park, HS and Park, NY (2004) Comparison of one-step RT-PCR and a nested PCR for the detection of canine distemper virus in clinical samples. Australian Veterinary Journal 82, 8386.CrossRefGoogle Scholar
Sierra-Honigmann, AM, Rubin, SA, Estafanous, MG, Yolken, RH and Carbone, KM (1993) Borna disease virus in peripheral blood mononuclear and bone marrow cells of neonatally and chronically infected rats. Journal of Neuroimmunology 45, 3136.CrossRefGoogle ScholarPubMed
Silver, N, Best, S, Jiang, J and Thein, SL (2006) Selection of housekeeping genes for gene expression studies in human reticulocytes using real-time PCR. BMC Molecular Biology 7, 33.CrossRefGoogle ScholarPubMed
Sirisinha, S and Charupatana, C (1970) Antibody responses in serum, secretions, and urine of man after parenteral administration of vaccines. Infection and Immunity 2, 2937.CrossRefGoogle ScholarPubMed
Smith, DR, Gray, JT, Moxley, RA, Younts-Dahl, SM, Blackford, MP, Hinkley, S, Hungerford, LL, Milton, CT and Klopfenstein, TJ (2004) A diagnostic strategy to determine the Shiga toxin-producing Escherichia coli O157 status of pens of feedlot cattle. Epidemiology and Infection 132, 297302.CrossRefGoogle ScholarPubMed
Spalenza, V, Girolami, F, Bevilacqua, C, Riondato, F, Rasero, R, Nebbia, C, Sacchi, P and Martin, P (2011) Identification of internal control genes for quantitative expression analysis by real-time PCR in bovine peripheral lymphocytes. Veterinary Journal 189, 278283.CrossRefGoogle ScholarPubMed
Stefl, R, Skrisovska, L and Allain, FH (2005) RNA sequence- and shape-dependent recognition by proteins in the ribonucleoprotein particle. EMBO Reports 6, 3338.CrossRefGoogle ScholarPubMed
Streckfus, CF and Bigler, LR (2002) Saliva as a diagnostic fluid. Oral Diseases 8, 6976.CrossRefGoogle ScholarPubMed
Takehara, S, Yanagishita, M, Podyma-Inoue, KA and Kawaguchi, Y (2013) Degradation of MUC7 and MUC5B in human saliva. PLoS One 8, e69059.CrossRefGoogle ScholarPubMed
Thellin, O, Zorzi, W, Lakaye, B, De Borman, B, Coumans, B, Hennen, G, Grisar, T, Igout, A and Heinen, E (1999) Housekeeping genes as internal standards: use and limits. Journal of Biotechnology 75, 291295.CrossRefGoogle ScholarPubMed
Thomas, BW, Champoux, M, Suomi, SJ and Gunnar, MR (1995) Salivary cortisol in nursery-reared rhesus monkeys: reactivity to peer interactions and altered circadian activity. Developmental Psychobiology 28, 257267.CrossRefGoogle Scholar
Thornton, DJ, Khan, N, Mehrotra, R, Howard, M, Veerman, E, Packer, NH and Sheehan, JK (1999) Salivary mucin MG1 is comprised almost entirely of different glycosylated forms of the MUC5B gene product. Glycobiology 9, 293302.CrossRefGoogle ScholarPubMed
To, KK, Tsang, OT, Yip, CC, Chan, KH, Wu, TC, Chan, JM, Leung, WS, Chik, TS, Choi, CY, Kandamby, DH, Lung, DC, Tam, AR, Poon, RW, Fung, AY, Hung, IF, Cheng, VC, Chan, JF and Yuen, KY (2020) Consistent detection of 2019 novel coronavirus in saliva. Clinical infectious Diseases 71, 841843.CrossRefGoogle ScholarPubMed
Tominaga, S, FUKUSHIMA, K, Nishizaki, K, Watanabe, S, Masuda, Y and Ogura, H (1996) Presence of human papillomavirus type 6f in tonsillar condyloma acuminatum and clinically normal tonsillar mucosa. Japanese Journal of Clinical Oncology 26, 393397.CrossRefGoogle ScholarPubMed
Tong, ZG, Gao, ZH, Wang, F, Zhou, J and Zhang, Z (2009) Selection of reliable reference genes for gene expression studies in peach using real-time PCR. BMC Molecular Biology 10, 71.CrossRefGoogle ScholarPubMed
Tristan, C, Shahani, N, Sedlak, TW and Sawa, A (2011) The diverse functions of GAPDH: views from different subcellular compartments. Cellular Signalling 23, 317323.CrossRefGoogle ScholarPubMed
Vandesompele, J, De Preter, K, Pattyn, F, Poppe, B, Van Roy, N, De Paepe, A and Speleman, F (2002) Accurate normalization of real-time quantitative RT-PCR data by geometric averaging of multiple internal control genes. Genome Biology 3, research0034. https://genomebiology.biomedcentral.com/articles/10.1186/gb-2002-3-7-research0034#article-infoCrossRefGoogle ScholarPubMed
Vinagre, C, Martinez, MJ, Avendano, LF, Landaeta, M and Pinto, ME (2003) Virology of infantile chronic recurrent parotitis in Santiago de Chile. Journal of Medical Virology 70, 459462.CrossRefGoogle ScholarPubMed
Walsh, KA, Jordan, K, Clyne, B, Rohde, D, Drummond, L, Byrne, P, Ahern, S, Carty, PG, O'brien, KK, O'murchu, E, O'neill, M, Smith, SM, Ryan, M and Harrington, P (2020) SARS-CoV-2 detection, viral load and infectivity over the course of an infection. The Journal of Infection 81, 357371.CrossRefGoogle ScholarPubMed
Wang, P and Heitman, J (2005) The cyclophilins. Genome Biology 6, 226.CrossRefGoogle ScholarPubMed
Wang, Y, Zhao, Y, Li, J, Liu, H, Ernst, CW, Liu, X, Liu, G, Xi, Y and Lei, M (2015) Evaluation of housekeeping genes for normalizing real-time quantitative PCR assays in pig skeletal muscle at multiple developmental stages. Gene 565, 235241.CrossRefGoogle ScholarPubMed
Weiser, AC, Poonsuk, K, Bade, SA, Gauger, PC, Rotolo, M, Harmon, K, Gonzalez, WM, Wang, C, Main, R and Zimmerman, JJ (2018) Effects of sample handling on the detection of porcine reproductive and respiratory syndrome virus in oral fluids by reverse-transcription real-time PCR. Journal of Veterinary Diagnostic Investigation 30, 807812.CrossRefGoogle ScholarPubMed
Wills, RW, Zimmerman, JJ, Yoon, KJ, Swenson, SL, Mcginley, MJ, Hill, HT, Platt, KB, Christopher-Hennings, J and Nelson, EA (1997) Porcine reproductive and respiratory syndrome virus: a persistent infection. Veterinary Microbiology 55, 231240.CrossRefGoogle ScholarPubMed
Winer, J, Jung, CKS, Shackel, I and Williams, PM (1999) Development and validation of real-time quantitative reverse transcriptase–polymerase chain reaction for monitoring gene expression in cardiac myocytesin vitro. Analytical Biochemistry 270, 4149.CrossRefGoogle Scholar
Wittwer, CT, Herrmann, MG, Moss, AA and Rasmussen, RP (1997) Continuous fluorescence monitoring of rapid cycle DNA amplification. Biotechniques 22, 134138.CrossRefGoogle ScholarPubMed
Wollstein, M (1918) A further study of experimental parotitis. Journal of Experimental Medicine 28, 377–U13.CrossRefGoogle ScholarPubMed
Wong, DT (2006) Towards a simple, saliva-based test for the detection of oral cancer ‘oral fluid (saliva), which is the mirror of the body, is a perfect medium to be explored for health and disease surveillance’. Expert Review of Molecular Diagnostics 6, 267272.CrossRefGoogle ScholarPubMed
Yan, L, Toohey-Kurth, KL, Crossley, BM, Bai, J, Glaser, AL, Tallmadge, RL and Goodman, LB (2020) Inhibition monitoring in veterinary molecular testing. Journal of Veterinary Diagnostic Investigation 32, 758766.CrossRefGoogle ScholarPubMed
Zhao, H, Liu, J, Li, Y, Yang, C, Zhao, S, Liu, J, Liu, A, Liu, G, Yin, H, Guan, G and Luo, J (2016) Validation of reference genes for quantitative real-time PCR in bovine PBMCs transformed and non-transformed by theileria annulata. Korean Journal of Parasitology 54, 3946.CrossRefGoogle ScholarPubMed
Zheng, G, Wang, H, Zhang, X, Yang, Y, Wang, L, Du, L, Li, W, Li, J, Qu, A, Liu, Y and Wang, C (2013) Identification and validation of reference genes for qPCR detection of serum microRNAs in colorectal adenocarcinoma patients. PLoS One 8, e83025.CrossRefGoogle ScholarPubMed
Zhong, H and Simons, JW (1999) Direct comparison of GAPDH, β-actin, cyclophilin, and 28S rRNA as internal standards for quantifying RNA levels under hypoxia. Biochemical and Biophysical Research Communications 259, 523526.CrossRefGoogle ScholarPubMed
Figure 0

Table 1. Frequency of reference genes reported in published qPCR studies using the oral fluid matrix